M38XX’s output are matrix decoupled. A 6X6 decoupled matrix for calculation is provided in the calibration sheet when delivered. Standard protection level for M38XX is IP60 unless denoted as IP65. Some models come with O/L STOPS which are added mechanical overload stops offering extra overload protection to the sensor.
For models that do not have AMP or DIGITAL denoted in description, they have millivolt range low voltage outputs. If your PLC or data acquisition system (DAQ) requires an amplified analog signal (i.e.:0-10V), you will need an amplifier for the strain gauge bridge. If your PLC or DAQ requires digital output, or if you do not have a data acquisition system yet but would like to read digital signals to your computer, a data acquisition interface box or circuit board is required.
SRI Amplifier & Data Acquisition System:
1. Integrated version: AMP and DAQ can be integrated for those OD larger than 75mm, offering a smaller footprint for compact spaces. Contact us for more details.
2. Standard version: SRI amplifier M8301X. SRI data acquisition interface box M812X. SRI data acquisition circuit board M8123X.
More information can be found in the SRI 6 Axis F/T Sensor User's Manual and SRI M8128 User’s Manual.